PM75RSA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
75 Amperes/600 Volts
558
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C — — 1.0 mA
V
CE
= V
CES
, T
j
= 125°C——10mA
Diode Forward Voltage V
FM
-I
C
= 75A, V
D
= 15V, V
CIN
= 5V — 2.2 3.3 Volts
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 75A — 1.8 2.7 Volts
V
D
= 15V, V
CIN
= 0V, I
C
= 75A, — 1.85 2.78 Volts
T
j
= 125°C
Inductive Load Switching Times t
on
0.4 0.8 2.0 µS
t
rr
V
D
= 15V, V
CIN
= 0 ~ 115V — 0.15 0.3 µS
t
C(on)
V
CC
= 300V, I
C
= 75A — 0.4 1.0 µS
t
off
T
j
= 125°C — 2.0 2.9 µS
t
C(off)
— 0.5 1.0 µS
Brake Sector
Collector-Emitter Saturation Voltage V
CE(sat)
V
D
= 15V, V
CIN
= 0V, I
C
= 75A, — 2.7 3.5 Volts
T
j
= 25°C
V
D
= 15V, V
CIN
= 0V, I
C
= 75A, — 3.1 4.0 Volts
T
j
= 125°C
Diode Forward Voltage V
FM
-I
C
= 30A, V
D
= 15V, V
CIN
= 5V — 1.7 2.7 Volts
Collector Cutoff Current I
CES
V
CE
= V
CES
, T
j
= 25°C——1mA
V
CE
= V
CES
, T
j
= 125°C——10mA