557
PM75RSA060
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
75 Amperes/600 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Over Current Trip Level Inverter Part OC -20°C ≤ T ≤ 125°C 115 161 — Amperes
Over Current Trip Level Brake Part 39 53 — Amperes
Short Circuit Trip Level Inverter Part SC -20°C ≤ T ≤ 125°C — 241 — Amperes
Short Circuit Trip Level Brake Part — 79 — Amperes
Over Current Delay Time t
off(OC)
V
D
= 15V — 10 — µS
Over Temperature Protection OT Trip Level 111 118 125 °C
OT
R
Reset Level — 100 — °C
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
UV
R
Reset Level — 12.5 — Volts
Supply Voltage V
D
Applied between V
UP1
-V
UPC
, 13.5 15 16.5 Volts
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Circuit Current I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—4460mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—1318mA
Input ON Threshold Voltage V
CIN(on)
Applied between 1.2 1.5 1.8 Volts
Input OFF Threshold Voltage V
CIN(off)
U
P
, V
P
, W
P
, U
N
, V
N
, W
N
, B
r
1.7 2.0 2.3 Volts
PWM Input Frequency f
PWM
3-B Sinusoidal — 15 20 kHz
Fault Output Current I
FO(H)
V
D
= 15V, V
FO
= 15V — — 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V — 10 15 mA
Minimum Fault Output Pulse Width t
FO
V
D
= 15V 1.0 1.8 — mS
Kommentare zu diesen Handbüchern