Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724)925-7272
Phase Control Thyristor
2500 Amperes/Up to 2600 Volts
Electrical Characteristics, T
J
=25°
°°
°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Repetitive Peak Reverse Leakage
Current
I
RRM
T
J
=125°
°°
°C, V
R
=V
RRM
150 mA
Repetitive Peak Forward Leakage
Current
I
DRM
T
J
=125°
°°
°C, V
D
=V
DRM
150 mA
Peak On-State Voltage V
TM
T
J
=125°
°°
°C, I
TM
=2000A
Duty Cycle < 0.01%
1.22 V
Threshold Voltage, Low-level V
(TO)1
T
J
=125°
°°
°C, for 375A≤
≤≤
≤I
TM
<7800A
0.9496 V
Slope Resistance, Low-level r
T1
0.1234
mΩ
ΩΩ
Ω
Threshold Voltage, High-level
V
(TO)2
T
J
=125°
°°
°C, for I
TM
>7800A
1.10 V
Slope Resistance, High-level r
T2
0.1149
mΩ
ΩΩ
Ω
ABCD V
TM
Modeling Coefficients
A = 0.89085
B = -2.419 E-2
C = 8.257 E-5
D = 7.861 E-3
T
J
=125°
°°
°C, for 10A≤
≤≤
≤I
TM
<60,000A
A + B x Ln(I
tm
) + C x I
tm
+
D x Sqrt(I
tm
)
V
-
m
Ω
ΩΩ
Ω
−
−−
−
Typical Delay Time t
d
Tj = 125C, V
D
=1500V 3
µ
µµ
µs
Maximum Turn-Off Time t
q
T
J
=125°
°°
°C, I
T
=2000A, di
R
/dt=5A/µ
µµ
µs
dv/dt=1000V/µ
µµ
µs linear to 1000 V
250
µ
µµ
µs
Minimum Critical dv/dt -
Exponential to V
DRM
dv/dt
T
J
=125°
°°
°C
500
V/µ
µµ
µs
Gate Trigger Current I
GT
T
J
=25°
°°
°C, V
D
=12V
250 mA
Gate Trigger Voltage V
GT
T
J
=25°
°°
°C, V
D
=12V
4.2 V
Non-Triggering Gate Voltage V
GDM
T
J
=125°
°°
°C, V
D
=V
DRM
0.5 V
Peak Forward Gate Current I
GTM
20 A
Peak Reverse Gate Voltage V
GRM
20 V
Thermal Characteristics
Characteristics Symbol Min. Typ. Max. Units
Maximum Thermal Resistance, Double Sided
Cooling
Junction to Case
Case to Sink
R
Θ
ΘΘ
ΘJC
R
Θ
ΘΘ
ΘCS
.010
.002
°
°°
°C/W
°
°°
°C/W
TBS7262503DataSheet 9/1/99
TBS7
2500A