www.vishay.com For technical questions, contact: ind-modules@vishay.com
Document Number: 93490
2 Revision: 21-May-08
150U(R).. Series
Vishay High Power Products
Standard Recovery Diodes
(Stud Version), 150 A
Note
• The table above shows the increment of thermal resistance R
thJC
when devices operate at different conduction angles than DC
FORWARD CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum average forward current
at case temperature
I
F(AV)
180° conduction, half sine wave
150 A
125 °C
Maximum RMS forward current I
F(RMS)
DC at 110 °C 235
A
Maximum peak, one cycle forward,
non-repetitive surge current
I
FSM
t = 10 ms
No voltage
reapplied
Sinusoidal half wave,
initial T
J
= T
J
maximum
3000
t = 8.3 ms 3140
Maximum I
2
t for fusing I
2
t
t = 10 ms 45
kA
2
s
t = 8.3 ms 41
Slope resistance r
f
T
J
= T
J
maximum 0.97 mΩ
Threshold voltage V
F(T0)
0.80
V
Maximum forward voltage drop V
FM
I
pk
= 600 A, T
J
= 25 °C, t
p
= 10 ms sinusoidal wave 1.47
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS VALUES UNITS
Maximum junction operating
and storage temperature range
T
J
, T
Stg
- 40 to 180 °C
Maximum thermal resistance,
junction to case
R
thJC
DC operation 0.3
K/W
Maximum thermal resistance,
case to heatsink
R
thCS
Mounting surface, smooth, flat and greased 0.1
Maximum allowed
mounting torque + 0 - 20 %
minimum Not lubricated threads 17
N · m
maximum Lubricated threads 14.5
Approximate weight 130 g
Case style See dimensions - link at the end of datasheet DO-205AA (DO-8)
ΔR
thJC
CONDUCTION
CONDUCTION ANGLE SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION TEST CONDITIONS UNITS
180°
0.031 0.023
T
J
= T
J
maximum K/W
120°
0.038 0.040
90°
0.048 0.053
60°
0.071 0.075
30°
0.120 0.121
Kommentare zu diesen Handbüchern